State State Name Blinking Amber Pattern Problem Description Suggested Resolution
If none of the memory
failed, replace the
motherboard.
S7 USB
3 blinks > short pause >
4 blinks > long pause >
repeats
Storage Subsystem
failure
Possible storage device
conguration in progress
or storage subsystem
failure.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one
storages on motherboard
to determine which one
failed.
If identied the storage
failed, replace the
storage.
If identied the storage
failed, replace the
storage.
S8 MEM
3 blinks > short pause >
5 blinks > long pause >
repeats
Memory conguration or
incompatible error
Memory subsystem
conguration activity is in
progress. No memory
modules were detected.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one the
memory on motherboard
to determine which one
failed. Also, combining
the conguration to
validate appropriate
combination.
If identied the
component failed, replace
the component.
If none of the component
failed, replace the
motherboard.
S9 MBF
3 blinks > short pause >
6 blinks > long pause >
repeats
System board failure
Fatal system board failure
detected.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one the
component on
motherboard to
determine which one
failed.