interface Port-channel 3
no ip address
channel-member TenGigabitEthernet 1/1/8/1
shutdown
DellEMC(conf-if-po-3)#
Configuring the Minimum Oper Up Links in a Port Channel
You can configure the minimum links in a port channel (LAG) that must be in oper up status to consider the port channel to be
in oper up status.
To set the oper up status of your links, use the following command.
Enter the number of links in a LAG that must be in oper up status.
INTERFACE mode
minimum-links number
The default is 1.
Example of Configuring the Minimum Oper Up Links in a Port Channel
DellEMC#config t
DellEMC(conf)#int po 1
DellEMC(conf-if-po-1)#minimum-links 5
DellEMC(conf-if-po-1)#
Adding or Removing a Port Channel from a VLAN
As with other interfaces, you can add Layer 2 port channel interfaces to VLANs. To add a port channel to a VLAN, place the
port channel in Layer 2 mode (by using the switchport command).
To add or remove a VLAN port channel and to view VLAN port channel members, use the following commands.
Add the port channel to the VLAN as a tagged interface.
INTERFACE VLAN mode
tagged port-channel id number
An interface with tagging enabled can belong to multiple VLANs.
Add the port channel to the VLAN as an untagged interface.
INTERFACE VLAN mode
untagged port-channel id number
An interface without tagging enabled can belong to only one VLAN.
Remove the port channel with tagging enabled from the VLAN.
INTERFACE VLAN mode
no tagged port-channel id number
or
no untagged port-channel id number
Identify which port channels are members of VLANs.
EXEC Privilege mode
show vlan
Configuring VLAN Tags for Member Interfaces
To configure and verify VLAN tags for individual members of a port channel, perform the following:
1. Configure VLAN membership on individual ports
INTERFACE mode
DellEMC(conf-if)#vlan tagged 2,3-4
2. Use the switchport command in INTERFACE mode to enable Layer 2 data transmissions through an individual interface
388