Concept Guide

Table Of Contents
Stack Master Election
The stack elects a master and standby unit at bootup time based on two criteria.
Unit priority User-configurable. The range is from 1 to 14. A higher value (14) means a higher priority. The default is 0.
By removing the stack-unit priority using the no stack-unit priority command, you can set the priority back to the
default value of zero. The unit with the highest priority is elected the master management unit; the unit with the second
highest priority is elected the standby unit.
MAC address (in case of priority tie) The unit with the higher MAC value becomes the master unit. The stack takes
the MAC address of the master unit and retains it unless it is reloaded.
To view which switch is the stack master, enter the show system command.
DellEMC#show system
Stack MAC : 34:17:eb:f2:94:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 14
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 51 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:94:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up UNKNOWN up 10704
1 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
1 1 up up 10134 up 10031
1 2 up up 10031 up 10031
1 3 up up 10031 up 10031
Speed in RPM
-- Unit 2 --
Unit Type : Standby Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 10
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 52 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:83:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 1 up UNKNOWN up 10768
Stacking