For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port/subport information.
For a 50-Gigabit Ethernet interface, enter the keyword fiftyGigE then the
slot/port/subport information.
For a 100-Gigabit Ethernet interface, enter the keyword hundredGigE then
the slot/port information.
Defaults Not configured.
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.12.0 Introduced on the S4810.
Legacy E-Series
command.
Related
Commands
fefd enable far-end failure detection.
fefd-global interval
Configure an interval between FEFD control packets.
Syntax
fefd-global interval seconds
To return to the default value, use the no fefd-global interval command.
Parameters
seconds
Enter a number as the time between FEFD control packets. The range is from 3 to
300 seconds. The default is 15 seconds.
Defaults 15 seconds
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell