Reference Guide

Table Of Contents
The following is an example of the show system brief command to view the stack summary information.
DellEMC#show system brief
Stack MAC : 34:17:eb:f2:94:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
1 Management online S4048-ON S4048-ON 1-0(0-5005) 72
2 Standby online S4048-ON S4048-ON 1-0(0-5005) 72
3 Member online S4048-ON S4048-ON 1-0(0-5005) 72
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up UNKNOWN up 10736
1 2 absent absent 0
2 1 up UNKNOWN up 10768
2 2 down UNKNOWN down 0
3 1 up UNKNOWN up 10672
3 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
1 1 up up 10134 up 10031
1 2 up up 10031 up 9929
1 3 up up 10031 up 10031
2 1 up up 10031 up 10031
2 2 up up 10031 up 10031
2 3 up up 10031 up 10134
3 1 up up 10031 up 10134
3 2 up up 10031 up 10031
3 3 up up 10031 up 10031
Speed in RPM
DellEMC#
The following example shows the show system stack-ports command.
DellEMC#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
1/56 3/56 40 up up
1/60 3/60 40 up up
3/48 40 up down
3/52 40 up down
3/56 0/56 40 up up
3/60 0/60 40 up up
Influencing Management Unit Selection on a Stack
Stack priority is the system variable that Dell EMC Networking OS uses to determine which units in the stack are the master
and standby management units. If multiple units tie for highest priority, the unit with the highest MAC address prevails.
If management was determined by priority only, a change in management occurs when:
the management unit is powered down or a failover occurs.
you disconnect the management unit from the stack.
When the management unit fails, the unit disappears from the stack topology. At that time, the standby unit detects the
communication loss and switches from the standby unit role to the management unit role in the stack. From the remaining units
930
Stacking