White Papers

Table Of Contents
Version Description
9.5(0.1) Introduced on the Z9500.
9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
Example
DellEMC(conf)# show logging auditlog
Related
Commands
clear logging auditlog clear the audit log.
show logging driverlog stack-unit
Display the driver log for the specified hardware component.
Syntax
show logging driverlog stack-unit stack-unit-number
Parameters
stack-unit
stack-
unit-number
Enter the keywords stack-unit followed by the stack member ID of the switch
for which you want to display the driver log.
defaults none
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-
Mux (PMUX) mode only.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
Example
DellEMC#show logging driverlog stack-unit 1
0:Task(tUsrRoot): [ 491677]PSU FanCtrl Drv ERR:
ssnDrvPoePsuEepromWriteEnable : 66 - Psu 1 is Not Present Cannot enable
1:Task(tUsrRoot): [ 338]PSU FanCtrl Drv ERR: ssnDrvPsuFanCtrlInit :
118 - Cannot enable psu -127228353
2:Task(tUsrRoot): [ 6876]EEPROM LIB ERR:
Simple Network Management Protocol (SNMP) and Syslog 1497