Users Guide

Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON and Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also
acts as defaults when the link-level flow control is enabled on one or more interfaces.
Enables priority flow control or enhance transmission selection on interface.
For ETS functioning, first assign the etsacl space using the cam-acl command.
DellEMC(conf)#cam-acl l2acl 2 ipv4acl 0 ipv6acl 0 ipv4qos 2 l2qos 0 l2pt
0 ipmacacl 0 vman-qos 0 fcoeacl 2 etsacl 1 iscsi 2
Related
Commands
dcb <ets | pfc> enable enable priority flow control or enhanced transmission selection on interface.
clear ets counters
Clear all ETS TLV counters on an interface.
Syntax
clear ets counters port-type slot/port[/subport]
Parameters
port-type Enter the keywords port-type then the slot/port information. Enter the subport
number if a port is fanned-out into 10G ports.
Defaults None
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON and Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Data Center Bridging (DCB) 487