White Papers

Table Of Contents
Service Provider Bridging
Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider
Backbone Bridging as described in the Dell EMC Networking OS Configuration Guide Service Provider Bridging section.
This section includes command line information (CLI) for the Dell EMC Networking OS Layer 2 Protocol Tunneling (L2PT). L2PT
enables protocols to tunnel through an 802.1q tunnel.
Dell EMC Networking OS supports L2PT on Dell EMC Networking OS.
For more information, see VLAN Stacking, Spanning Tree Protocol (STP), and GARP VLAN Registration (GVRP).
Important Points to Remember
L2PT is enabled at the interface VLAN-Stack VLAN level. For more information about Stackable VLAN (VLAN-Stacking)
commands, see VLAN Stacking.
The default behavior is to disable protocol packet tunneling through the 802.1q tunnel.
Rate-limiting is required to protect against bridge protocol data units (BPDU) attacks.
A port channel (including through link aggregation control protocol [LACP]) can be configured as a VLAN-Stack access or
trunk port.
Address resolution protocol (ARP) packets work as expected across the tunnel.
Far-end failure detection (FEFD) works the same as with Layer 2 links.
Protocols that use Multicast MAC addresses (for example, open shortest path first [OSPF]) work as expected and carry
over to the other end of the VLAN-Stack VLAN.
Topics:
debug protocol-tunnel
protocol-tunnel
protocol-tunnel destination-mac
protocol-tunnel enable
protocol-tunnel rate-limit
show protocol-tunnel
debug protocol-tunnel
Enable debugging to ensure incoming packets are received and rewritten to a new MAC address.
Syntax
debug protocol-tunnel interface {in | out | both} [vlan vlan-id] [count
value]
To disable debugging, use the no debug protocol-tunnel interface {in | out | both}
[vlan vlan-id] [count value] command.
Parameters
interface Enter one of the following interfaces and the interface information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port/subport information.
For a 25-Gigabit Ethernet interface, enter the keyword twentyFiveGigE
then the slot/port/subport information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port/subport information.
For a 50-Gigabit Ethernet interface, enter the keyword fiftyGigE then the
slot/port/subport information.
49
1442 Service Provider Bridging