Release Notes
Table Of Contents
- Dell S6100–ON System Release Notes, OS Version 9.14(2.10)
- Document Revision History
- Requirements
- New Dell Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to the Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the ONIE Package for the S6100-ON System
- Upgrading the DIAG Package for the S6100-ON System
- Installing Dell EMC Networking OS on the S6100-ON using ONIE
- Upgrading the S6100-ON Dell EMC Networking OS Image using Dell EMC Networking OS CLI
- Upgrade the Boot Selector and Boot Flash Images from Dell EMC Networking OS
- Upgrade the CPLD Images
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-IAP
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-FPGA
- Upgrading the OOB-FPGA Image
- Uninstalling the Dell EMC Networking OS
- Installing a Third Party Operating System
- Contacting Dell EMC
Upgrading the Switchcard-CPLD Image
The S6100-ON system with Dell EMC Networking OS Version 9.14(2.10) requires switchcard-cpld image 5.
NOTE: The upgrade fpga-image switchcard-cpld stack-unit 1 booted command is hidden when using the
feature in the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the
S6100–ON.
NOTE: Ensure that the BIOS version is 3.25.0.0-6. You can verify this version using the show system stack-unit 1
command.
To upgrade the CPLD image, follow these steps.
1. Upgrade the switchcard-CPLD image.
EXEC Privilege Mode
upgrade fpga-image switchcard-cpld stack-unit <1> booted
Current information for the system:
========================================================================
Card Device Name Current Version New Version
------------------------------------------------------------------------
Unit1 S6100-ON SWITCHCARD CPLD 4 5
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for stack-unit 1 [yes/no]: yes
Cpld upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
Unit 1 Cpld upgrade successful Unit 1. Please power cycle to take effect.
DellEMC#May 18 12:41:34: %S6100-ON:1 %DOWNLOAD-6-FPGA_UPGRADE: stack-unit 1 fpga
upgrade success.
Upgrading the CXP Module CPLD image
The S6100-ON system with Dell EMC Networking OS Version 9.14(2.10) requires CXP MODULE CPLD image 5. To display the
CXP module CPLD version currently running on an S6100-ON, use the show revision command.
NOTE:
The upgrade fpga-image mod-id stack-unit 1 booted command is hidden when using the feature in
the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the S6100–ON.
To upgrade the CPLD image, follow these steps.
1. Upgrade the CXP module CPLD image.
EXEC Privilege Mode
upgrade fpga-image mod-id stack-unit 1 booted
NOTE: In this example, the CXP Module is in slot 2.
DellEMC#upgrade fpga-image 2 stack-unit 1 booted
Current information for the system:
========================================================================
Card Device Name Current Version New Version
------------------------------------------------------------------------
Unit1 S6100-ON IOM CPLD2 4 5
***********************************************************************