CLI Guide

Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.1.(0.0) Updated to support OpenFlow.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 Augmented to display PVLAN data for the C-Series and S-Series and revised the
output to include the Description field to display a user-entered VLAN description.
7.6.1.0 Introduced on the S-Series and revised the output to display Native VLAN.
7.5.1.0 Introduced on the C-Series.
pre-6.2.1.1 Introduced on the E-Series.
Usage
Information
The following describes the show vlan command shown in the following example.
Column
Heading
Description
(Column 1 no
heading)
asterisk symbol (*) = Default VLAN
G = GVRP VLAN
P = primary VLAN
C = community VLAN
I = isolated VLAN
O = OpenFlow
NUM Displays existing VLAN IDs.
Status Displays the word Inactive for inactive VLANs and the word Active for active
VLANs.
Q
Displays G for GVRP tagged
M for member of a VLAN-Stack VLAN
T for tagged interface
U for untagged interface
x (not capitalized x) for Dot1x untagged
X (capitalized X) for Dot1x tagged
o (not capitalized o) for OpenFlow untagged
O (capitalized O) for OpenFlow tagged
H for VSN tagged
i (not capitalized i) for Internal untagged
I (capitalized I) for Internal tagged
v (not capitalized v) for VLT untagged
V (capitalized V) for VLT tagged
Ports Displays the type, slot, and port information.
Po = port channel
Te = ten-gigabit Ethernet
Fo = forty-gigabit Ethernet
Layer 2 911