White Papers

Table Of Contents
Version Description
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command
Usage
Information
After entering the banner login command, type one or more spaces and a delineator character. Enter the
banner text then the second delineator character. When the user is connected to the router, if a message
of the day banner is configured, it displays first. If no message of the day banner is configured, the login
banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Related
Commands
banner exec enables the display of a text string when you enter EXEC mode.
banner login sets a banner to display after successful login to the system.
cam-acl
Allocate content addressable memory (CAM) for IPv4 and IPv6 ACLs.
Syntax
cam-acl {default | l2acl number ipv4acl number ipv6acl number ipv4qos
number l2qos number l2pt number ipmacacl number [vman-qos | vman-dual-qos]
number {fcoeacl number} {openflow number}
Parameters
default Use the default CAM profile settings and set the CAM as follows:
L2Acl : 2
Ipv4Acl : 2
Ipv6Acl : 0
Ipv4Qos : 2
L2Qos : 2
L2PT : 0
IpMacAcl : 1
VmanQos : 0
EtsAcl : 0
FcoeAcl : 0
ipv4pbr : 0
vrfv4Acl : 0
Openflow : 0
fedgovacl : 0
nlbclusteracl: 0
ipv4udfmirracl: 0
ipv4mirracl: 0
cam-acl {default
| l2acl
number
ipv4acl
number
ipv6acl
number
,
ipv4qos
number
l2qos
number
l2pt
numb
er
ipmacacl
number
ecfmacl
number
[vman-
qos | vman-dual-
qos
number
}
Allocate space to each CAM region.
Enter the CAM profile name then the amount of CAM space to be allotted. The
total space allocated must equal to 9. The ipv6acl range must be a factor of 2.
Enter 3, 6, or 9 for the number of OpenFlow FP blocks.
3: Creates 245 entries for use by Openflow controller (256 total entries minus
the 11 entries reserved for internal functionality)
6: Creates 501 entries for use by Openflow controller (512 total entries minus
the 11 entries reserved for internal functionality)
9: Creates 757 entries for use by Openflow controller (768 total entries minus
the 11 entries reserved for internal functionality)
Command Modes CONFIGURATION
Control and Monitoring 85