Release Notes
Table Of Contents
- Dell EMC System S4048–ON 9.14(2.9P1) Release Notes
- Document Revision History
- Supported Hardware
- Supported Software
- New Dell EMC Networking OS Version 9.14(2.9) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the sub-components
- Upgrading ONIE on the S4048-ON
- Upgrading the S4048-ON Dell EMC Networking OS Image using the Dell EMC Networking OS CLI
- Installing Dell EMC Networking OS on the S4048-ON using ONIE
- Uninstalling Dell EMC Networking OS from the S4048-ON
- Support Resources
CPGC Memtest for Channel 0 .................. PASS
ECC enabled: channel 0 DECCCTRL_DUNIT_REG=0x000200F3
POST:
RTC Battery OK at last cold boot
RTC date Tuesday 12/15/2020 23:34:05
POST SPD test ............................... PASS
POST Lower DRAM Memory test
.... Perf cnt (curr,fixed): 0x15A49BCF6,0x164D87D38
POST Lower DRAM Memory test ................. PASS
POST Lower DRAM ECC check ................... PASS
DxE POST
POST PCI test ............................... PASS
POST NVRAM check ............................ PASS
POST overall test results ................... PASS
NVRAM at POST exit: 00 97 00 E6 03 03 00 EA
Grub 1.99~rc1 (Dell EMC)
Built by root at gbbdev-maa-01 on Tue_Dec_15_14:16:54_UTC_2020
S4000 Boot Flash Label 3.21.2.9 NetBoot Label 3.21.2.9
NOTE: For the latest diagnostics version, see the Dell EMC S4048–Open Networking (ON) System Release Notes.
5. Upgrade the BIOS image using the BIOS image and Flashrom utility included with the diagnostic package.
ONIE:/ # tftp -g -r S4000-BIOS-x.x.x.x-16MB.bin 10.11.8.12S4000-BIOS-x.x.x.x. 100% |
*******************************| 8192k 0:00:00 ETA
ONIE:/ #
ONIE:/ #
ONIE:/ # flashrom -E -p internal
Erasing and writing flash chip... Erase/write done.
ONIE:/ # flashrom -w ./ S4000-BIOS-x.x.x.x-16MB.bin -p internal
Erasing and writing flash chip... Erase/write done.
Verifying flash... VERIFIED.
ONIE:/ #
Upgrading the S4048-ON Dell EMC Networking OS
Image using the Dell EMC Networking OS CLI
NOTE:
If you are upgrading from Dell EMC Networking OS version 9.9(0.0P18) or earlier, you cannot directly upgrade to
version 9.14(2.9) or above. Upgrade to version 9.10(0.0) or above first and then upgrade to the required version.
Bare Metal Provisioning
NOTE:
If you are using Bare Metal Provisioning (BMP), see the Bare Metal Provisioning topic in the Dell EMC Networking
OS Configuration Guide or the Open Automation Guide.
Manual Upgrade Procedure
Follow these steps carefully to upgrade your S4048-ON systems:
1. Dell EMC Networking recommends that you back up your startup configuration and any important files and directories to an
external media prior to upgrading the system.
2. Upgrade the Dell EMC Networking OS in flash partition A: or B:
EXEC Privilege Mode
upgrade system [flash: | ftp: stack-unit <1-6> | tftp: | scp: | usbflash:] [A: | B:]
DellEMC#upgrade system tftp: a:
Address or name of remote host []: 10.16.127.143
Source file name []: FTOS-SK-9.14.2.9.bin
13