Release Notes

-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 0
Hardware Rev : 1.0
Num Ports : 72
Up Time : 15 min, 26 sec
Dell EMC Networking OS Version : 9.14(2.9)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.21.2.9
Boot Selector : 3.21.0.0-6
Memory Size : 2127560704 bytes
Temperature : 36C
Voltage : ok
Upgrade the GRUB or Boot Flash
To upgrade the GRUB or Boot Flash from Dell EMC Networking OS, perform the following steps:
1. Upgrade the S4048-ON Boot Flash image.
EXEC Privilege Mode
upgrade boot bootflash-image stack-unit [<id> | all] [booted | flash: | ftp: | scp: |
tftp: | usbflash:]
DellEMC#upgrade boot bootflash-image stack-unit 1 booted
Current Boot information in the system:
======================================================================
Card BootFlash Current Version New Version
----------------------------------------------------------------------
Unit1 Boot Flash 3.21.2.3 3.21.2.9
***********************************************************************
* Warning - Upgrading boot flash is inherently risky and should only *
* be attempted when necessary. A failure at this upgrade may cause *
* a board RMA. Proceed with caution ! *
***********************************************************************
Proceed upgrade Boot Flash image for stack-unit 1 [yes/no]: y
!!!!!
Bootflash image upgrade for stack-unit 1 completed successfully.
DellEMC#
Upgrade the CPLD
The S4048-ON system with Dell EMC Networking OS Version 9.14(2.9) requires System CPLD revision 15.2, Master CPLD
revision 12, and Slave CPLD revision 5.
NOTE:
If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions
regarding the CPLD revision, contact technical support.
Verify that a CPLD upgrade is required
Use the following command to identify the CPLD version:
DellEMC#show revision
9