Administrator Guide

Table Of Contents
Key Description
m Change the view from a single interface to all interfaces on the line card or visa-
versa.
c Refresh the view.
b Change the counters displayed from Packets on the interface to Bytes.
r Change the [delta] column from change in the number of packets/bytes in the last
interval to rate per second.
l Change the view to the next interface on the line card, or if in line card mode, the
next line card in the chassis.
a Change the view to the previous interface on the line card, or if in line card mode,
the previous line card in the chassis.
T Increase the screen refresh rate.
t Decrease the screen refresh rate.
q Return to the CLI prompt.
Example
Dell# monitor interface fortyGigE 2
Dell Networking operating system uptime is 3 minute(s)
Monitor time: 00:00:00 Refresh Intvl.: 2s
Interface Link In Packets [delta] Out
Packets [delta]
Fo 2/4 Up 2 0
2 0
Fo 2/8 Down 0 0
0 0
Fo 2/12 Down 0 0
0 0
Fo 2/16 Up 1 0
1 0
Fo 2/20 Up 1 0
1 0
Fo 2/24 Down 0 0
0 0
Fo 2/28 Up 2 0
1 0
Fo 2/32 Up 1 0
2 0
Fo 2/36 Down 0 0
0 0
Fo 2/40 Up 0 0
2 0
Fo 2/44 Up 0 0
2 0
Fo 2/48 Down 0 0
0 0
Fo 2/52 Down 0 0
0 0
Fo 2/56 Down 0 0
0 0
Fo 2/60 Down 0 0
0 0
Fo 2/64 Down 0 0
0 0
Fo 2/68 Down 0 0
0 0
Fo 2/72 Down 0 0
0 0
Fo 2/76 Down 0 0
0 0
Fo 2/80 Down 0 0
0 0
Fo 2/84 Down 0 0
Interfaces
729