Administrator Guide
Example of the show sflow command when the sflow max-header-size extended is configured globally
DellEMC(conf-if-te-1/10)#show sflow
sFlow services are enabled
Egress Management Interface sFlow services are disabled
Global default sampling rate: 32768
Global default counter polling interval: 86400
Global default extended maximum header size: 256 bytes
Global extended information enabled: none
1 collectors configured
Collector IP addr: 100.1.1.12, Agent IP addr: 100.1.1.1, UDP port: 6343 VRF: Default
0 UDP packets exported
0 UDP packets dropped
0 sFlow samples collected
Example of viewing the sflow max-header-size extended on an Interface Mode
DellEMC#show sflow interface tengigabitethernet 1/1
Te 1/1
sFlow type :Ingress
Configured sampling rate :16384
Actual sampling rate :16384
Counter polling interval :20
Extended max header size :256
Samples rcvd from h/w :0
Example of the show running-config sflow Command
DellEMC#show running-config sflow
!
sflow collector 100.1.1.12 agent-addr 100.1.1.1
sflow enable
sflow max-header-size extended
DellEMC#show run int tengigabitEthernet 1/10
!
interface TenGigabitEthernet 1/10
no ip address
switchport
sflow ingress-enable
sflow max-header-size extended
no shutdown
sFlow Show Commands
Dell EMC Networking OS includes the following sFlow display commands.
● Displaying Show sFlow Globally
● Displaying Show sFlow on an Interface
● Displaying Show sFlow on a Line Card
Displaying Show sFlow Global
To view sFlow statistics, use the following command.
● Display sFlow configuration information and statistics.
EXEC mode
show sflow
The first bold line indicates sFlow is globally enabled.
The second bold lines indicate sFlow is enabled on Te 1/16 and Te 1/17
DellEMC#show sflow
sFlow services are enabled
824
sFlow