Service Manual
Example of the show running-config sflow Command
sFlow Show Commands
Dell EMC Networking OS includes the following sFlow display commands.
● Displaying Show sFlow Globally
● Displaying Show sFlow on an Interface
● Displaying Show sFlow on a Line Card
Displaying Show sFlow Global
To view sFlow statistics, use the following command.
● Display sFlow configuration information and statistics.
EXEC mode
show sflow
The first bold line indicates sFlow is globally enabled.
The second bold lines indicate sFlow is enabled on Hu 1/2/1 and Tf 1/2/2/1
DellEMC#show sflow
sFlow services are enabled
Global default sampling rate: 32768
Global default counter polling interval: 20
1 collectors configured
Collector IP addr: 133.33.33.53, Agent IP addr: 133.33.33.116, UDP port: 6343
77 UDP packets exported
0 UDP packets dropped
165 sFlow samples collected
69 sFlow samples dropped due to sub-sampling
Stack-unit 1 Port set 0 H/W sampling rate 8192
Displaying Show sFlow on an Interface
To view sFlow information on a specific interface, use the following command.
● Display sFlow configuration information and statistics on a specific interface.
EXEC mode
show sflow interface interface-name
The following example shows the show sflow interface command.
DellEMC#show sflow interface tengigabitethernet 1/1/1/1
Te 1/1/1/1
sFlow type :Ingress
Configured sampling rate :16384
Actual sampling rate :16384
Counter polling interval :20
Extended max header size :128
Samples rcvd from h/w :0
The following example shows the show running-config interface command.
DellEMC#show running-config interface tengigabitethernet 1/1/6/1
!
interface TenGigabitEthernet 1/1/6/1
no ip address
switchport
sflow ingress-enable
sFlow
833