Setup Guide

Table Of Contents
Field Description
Interface The unit/port ID of the connected stack port on this unit.
Link Speed Link Speed of the stack port (10 or 40) in Gb/s.
Admin Status The only currently listed status is Up.
Connection The stack port ID to which this units stack port is connected.
Example
DellEMC#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link
(Gb/s) Status Status
---------------------------------------------------------
1/4 5/4 42 up up
1/12 2/0 42 up up
2/1 0/120 42 up up
2/4 5/120 42 up up
5/4 0/4 42 up up
5/12 2/4 42 up up
Example (Status)
DellEMC#show system stack-ports status
Topology: Ring
Interface Link Speed Admin Link
(Gb/s) Status Status
--------------------------------------------
0/4 42 up up
0/120 42 up up
2/0 42 up up
2/4 42 up up
5/4 42 up up
5/120 42 up up
Example
(Topology)
DellEMC#show system stack-ports topology
Topology: Ring
Interface Connection
---------------------
0/4 5/4
0/120 2/0
2/0 0/120
2/4 5/120
5/4 0/4
5/120 2/4
DellEMC#
Related
Commands
reset stack-unit resets the designated stack member.
show hardware stack-unit displays the data plane or management plane input and output statistics
of the designated component of the designated stack member.
show system displays the current status of all stack members or a specific member.
stack-unit priority
Configure the ability of a switch to become the management unit of a stack.
Syntax
stack-unit stack-number priority priority-value
Parameters
stack-number
Enter the stack member unit identifier.
priority-value
This preference parameter allows you to specify the management priority of one
backup switch over another, with 1 as the lowest priority and 14 being the highest.
The switch with the highest priority value is chosen to become the management
unit if the active management unit fails or on the next reload.
1506 Stacking