Release Notes

upgrade mss-fpga-image rpm booted
DellEMC(standby)# upgrade mss-fpga-image rpm booted
Current information for the system:
=============================================================
Card Device Name Current Version New Version
-------------------------------------------------------------
CP FPGA 1 3.12 3.12
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for rpm 1 [yes/no]: y
c. Upgrade the MSS IAP image on the standby RPM. This operation takes about 5 minutes to complete.
EXEC Privilege mode
upgrade mss-iap-image rpm booted
DellEMC(standby)# upgrade mss-iap-image rpm booted
Current information for the system:
===============================================================
Card Device Name Current Version New Version
---------------------------------------------------------------
CP IAP 3.1 3.2
***********************************************************************
* Warning - Upgrading IAP is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for rpm 1 [yes/no]: y
IAP upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!System shall reboot in few minutes after FPGA/eNVM programming....
Please wait...
Upgrade result :
================
RPM1 IAP upgrade successful. Please power cycle the system manually to take effect.
d. Upgrade the CPLD image on the standby RPM.
EXEC Privilege mode
upgrade cpld-image rpm booted
DellEMC(standby)# upgrade cpld-image rpm booted
Current information for the system:
==================================================================
Card Device Name Current Version New Version
------------------------------------------------------------------
CP CPLD 3.4 3.7
***********************************************************************
* Warning - Upgrading CPLD is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for rpm 1 [yes/no]: y
CPLD upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
RPM0 CPLD upgrade successful. Please power cycle the system manually to take effect.
4. Upgrade the MSS FPGA image on the primary RPM. This upgrade requires that you failover the primary RPM so that it
becomes the standby. The upgrade mss-fpga-image rpm booted command is supported only on the standby RPM.
EXEC Privilege mode
a. Connect the C9010 console to the console port on the primary RPM and log in.
17