White Papers

Table Of Contents
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed uplink state group state to down: Group 3
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Tf 1/9
02:37:29: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Tf 1/10
02:38:31 : UFD: Group:3, UplinkState: UP
02:38:31: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed uplink state group state to up: Group 3
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-disabled:
Tf 1/11
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-disabled:
Tf 1/12
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-disabled:
Tf 1/13
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-disabled:
Tf 1/14
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Tf 1/15
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Tf 1/16
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Tf 1/17
02:38:53: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Tf 1/18
Displaying Uplink Failure Detection
To display information on the UFD feature, use any of the following commands.
Display status information on a specified uplink-state group or all groups.
EXEC mode
show uplink-state-group [group-id] [detail]
group-id: The values are from 1 to 16.
detail: displays additional status information on the upstream and downstream interfaces in each group.
Display the current status of a port or port-channel interface assigned to an uplink-state group.
EXEC mode
show interfaces interface
interface specifies one of the following interface types:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port/subport information.
For a 25-Gigabit Ethernet interface, enter the keyword twentyFiveGigE then the slot/port/subport information.
For a 50-Gigabit Ethernet interface, enter the keyword fiftyGigE then the slot/port/subport information.
For a 100-Gigabit Ethernet interface, enter the keyword hundredGigE then the slot/port/subport information.
For a port channel interface, enter the keywords port-channel then a number.
If a downstream interface in an uplink-state group is disabled (Oper Down state) by uplink-state tracking because an
upstream port is down, the message error-disabled[UFD] displays in the output.
Display the current configuration of all uplink-state groups or a specified group.
EXEC mode or UPLINK-STATE-GROUP mode
(For EXEC mode) show running-config uplink-state-group [group-id]
(For UPLINK-STATE-GROUP mode) show configuration
group-id: The values are from 1 to 16.
The following example shows viewing the uplink state group status.
The following example shows viewing the interface status with UFD information.
DellEMC#show interfaces twentyFiveGigE 1/15
twentyFiveGigE 1/15 is up, line protocol is down (error-disabled[UFD])
Hardware is Force10Eth, address is 00:01:e8:32:7a:47
Current address is 00:01:e8:32:7a:47
Interface index is 280544512
Internet address is not set
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed 25000 Mbit, Mode auto
Flowcontrol rx off tx off
Uplink Failure Detection (UFD)
881