White Papers

Table Of Contents
Example of Enabling an FC-MAP Value on a VLAN
DellEMC(conf-if-vl-10)# fip-snooping fc-map 0xOEFC01
NOTE: Configuring an FC-MAP value is only required if you do not use the default FC-MAP value (0x0EFC00).
Example of Configuring the ENode Server-Facing Port
DellEMC(conf)# interface tengigabitethernet 1/1/1
DellEMC(conf-if-te-1/1/1)# portmode hybrid
DellEMC(conf-if-te-1/1/1)# switchport
DellEMC(conf-if-te-1/1/1)# protocol lldp
DellEMC(conf-if-te-1/1/1-lldp)# dcbx port-role auto-downstream
NOTE: A port is enabled by default for bridge-ENode links.
Example of Configuring the FCF-Facing Port
DellEMC(conf)# interface tengigabitethernet 1/5/1
DellEMC(conf-if-te-1/5/1)# portmode hybrid
DellEMC(conf-if-te-1/5/1)# switchport
DellEMC(conf-if-te-1/5/1)# fip-snooping port-mode fcf
DellEMC(conf-if-te-1/5/1)# protocol lldp
DellEMC(conf-if-te-1/5/1-lldp)# dcbx port-role auto-upstream
Example of Configuring FIP Snooping Ports as Tagged Members of the FCoE VLAN
DellEMC(conf)# interface vlan 10
DellEMC(conf-if-vl-10)# tagged tengigabitethernet 1/1/1
DellEMC(conf-if-vl-10)# tagged tengigabitethernet 1/5/1
DellEMC(conf-if-te-1/1/1)# no shut
DellEMC(conf-if-te-1/5/1)# no shut
DellEMC(conf-if-vl-10)# no shut
After FIP packets are exchanged between the ENode and the switch, a FIP snooping session is established. ACLs are
dynamically generated for FIP snooping on the FIP snooping bridge/switch.
322
FIP Snooping