White Papers

Table Of Contents
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.4.1.0 Introduced
Usage
Information
This command applies to any physical interface with speed set to 10/100.
NOTE: Starting with Dell EMC Networking OS version 7.8.1.0, when you use a copper SFP2 module
with catalog number GP-SFP2-1T in the S25P model of the S-Series, you can manually set its speed
with the speed command. When you set the speed to 10 Mbps or 100 Mbps, you can also execute
the duplex command.
Related
Commands
negotiation auto enable or disables auto-negotiation on an interface.
duplex (Management interface)
Configure duplex mode on a management interface whose speed is set to 10/100 Mb/s.
S5000
Syntax
duplex {half | full}
To return to the default setting, use the no duplex command.
Parameters
half Enter the keyword half to set the physical interface to transmit only in one
direction.
full Enter the keyword full to set the physical interface to transmit in both
directions.
Defaults Not configured.
Command Modes INTERFACE
Command
History
Version 9.0(1.3) Introduced on the S5000.
Interfaces 687