White Papers

Table Of Contents
Example
Dell(conf)#fc zoneset test1
Dell(conf-fc-zoneset-test1)#member ?
WORD Zone Name
Dell(conf-fc-zoneset-test1)#member
Related
Commands
show fc zoneset displays the configured and active zoneset.
show fcoe-map displays the fabric parameters.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs and a SAN fabric. Apply
the FCoE map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name
Maximum: 32 alphanumeric characters.
Defaults None
Command Modes CONFIGURATION
INTERFACE
Supported Modes FullSwitch
Command
History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
9.0(1.3) Introduced on the S5000.
Usage
Information
An FCoE map is a template to map FCoE and FC parameters in a converged fabric. An FCoE map
virtualizes upstream FC ports on an NPIV proxy gateway to appear to downstream server CNA ports as
FCoE forwarder (FCF) ports on an FCoE network. When applied to FC and Ethernet ports on an NPIV
proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC bridge between an FC SAN and
an FCoE network. It provides necessary parameters to FCoE-enabled servers and switches to log in to a
SAN fabric.
On an FN IOM NPIV proxy gateway, an FCoE map is applied on fabric-facing FC ports and server-facing
Ethernet ports. Use the fcoe-map command to apply an FCoE map on an Ethernet port. Use the
fabric command to apply an FCoE map on an FC port.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN for storage traffic, the
destination SAN fabric (FC-MAP value), FCF priority, and the FIP keepalive (FKA) advertisement timeout.
To remove an FCoE map from an Ethernet interface, enter the no fcoe-map map-name command in
Interface configuration mode.
NOTE: In FCF F mode, you can create only 1 FCoE map. It doesnt get created automatically. If you
try to create more than 1 map, an error message is displayed.
Related
Commands
show fcoe-map displays the Fibre Channel and FCoE configuration parameters in FCoE maps.
fabric
Apply an FCoE map on a fabric-facing Fibre Channel (FC) port.
Syntax
fabric map-name
FC FLEXIO FPORT 427