CLI Guide

Table Of Contents
end-day
Enter the number of the day. The range is from 1 to 31. You can enter the name of
a month to change the order of the display to time day month year.
end-month
Enter the name of one of the 12 months in English. You can enter the name of a
day to change the order of the display to time day month year.
end-time
Enter the time in hours:minutes. For the hour variable, use the 24-hour format;
example, 17:15 is 5:15 pm.
end-year
Enter a four-digit number as the year. The range is from 1993 to 2035.
offset
(OPTIONAL) Enter the number of minutes to add during the summer-time period.
The range is from 1 to1440. The default is 60 minutes.
Defaults Not configured.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
Related
Commands
clock summer-time recurring sets a date (and time zone) on which to convert the switch to
daylight saving time each year.
show clock displays the current clock settings.
clock summer-time recurring
Set the software clock to convert to daylight saving time on a specific day each year.
Syntax
clock summer-time time-zone recurring [start-week start-day start-month
start-time end-week end-day end-month end-time [offset]]
To delete a daylight saving time zone configuration, use the no clock summer-time command.
Parameters
time-zone
Enter the three-letter name for the time zone. This name is displayed in the show
clock output. You can enter up to eight characters.
1560 System Time and Date