Setup Guide

Table Of Contents
Version Description
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S-Series and Z-Series.
Usage
Information
NOTE: This command also enables you to view information corresponding to a range of ports.
You can specify multiple ports as port-range. For example, if you want to display information
corresponding to all ports between 1 and 4, specify the port range as show interfaces
interface-type 1 - 4.
Example
DellEMC# show interfaces vlan 10
Vlan 10 is up, line protocol is down
Address is 90:b1:1c:f4:99:ce, Current address is 90:b1:1c:f4:99:ce
Interface index is 1107787786
Internet address is not set
Mode of IPv4 Address Assignment: NONE
DHCP Client-ID: 90b11cf499ce
MTU 1554 bytes, IP MTU 1500 bytes
LineSpeed auto
ARP type: ARPA, ARP Timeout 04:00:00
Last clearing of "show interface" counters 2d17h26m
Queueing strategy: fifo
Time since last interface status change: 2d17h26m
Input Statistics:
0 packets, 0 bytes
Output Statistics:
0 packets, 0 bytes, 0 underruns
show system stack-unit fanout configured
Displays the details about the fanned-out ports.
Syntax
show system stack-unit stack-unit-number fanout configured
Parameters
stack-unit
stack-
unit-number
The stack Unit ID of the device.
fanout
configured
Enter the keywords fanout configured to display the details about the
fanned-out ports.
Defaults None.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S4048T-ON.
9.10(0.0) Introduced on the S6100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(1.0) Introduced on the Z9100-ON.
Example
DellEMC#show system stack-unit 1 fanout configured
Configured fan out ports in stack-unit 1
Mod/Port Mode Speed
1/1 Quad 10G
1/3 Quad 10G
694 Interfaces