NOTE: This command also enables you to view information corresponding to a range of ports.
However, for Open Networking (ON) platforms the notation for specifying port range in the
command is different from how you specify in non-ON platforms.
For non-ON platforms, you can specify multiple ports as slot/port-range. For example, if you
want to display information corresponding to all ports between 1 and 4, specify the port range as
show interfaces interface-type 1/1 - 4.
For ON platforms, you can specify multiple ports as slot/port/[subport] - slot/port/
[subport]. For example, if you want to display information corresponding to all ports between 1
and 4, specify the port range as show interfaces interface-type 1/1/1 - 1/1/4.
Command Modes INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
The following is a list of the Dell EMC Networking OS version history for this command.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Enabled to display the command output even without enabling DCB.
9.9(0.0) Added support to display the interface configurations corresponding to a range of
ports.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
You can use this command even without enabling DCB.
Example
(Summary)
DellEMC#show int te 1/1 pfc statistics
Interface TenGigabitEthernet 1/1
Priority Rx XOFF Frames Rx Total Frames Tx Total Frames
-----------------------------------------------------------------
0 0 0 0
1 0 0 0
2 0 0 0
3 0 0 0
4 0 0 0
5 0 0 0
6 0 0 0
7 0 0 0
show stack-unit stack-ports pfc details
Displays the PFC configuration applied to ingress traffic on stacked ports, including PFC Operational mode on each unit with the
configured priorities, link delay, and number of pause packets sent and received.
Syntax
show stack-unit {all | stack-unit} stack-ports {all | port-number} pfc
details
Parameters
stack-unit
Enter the stack unit.
port-number
Enter the port number.
492 Data Center Bridging (DCB)