Rev. A00 June 2021 Dell EMC S5048F–ON System Release Notes, OS Version 9.14(2.10) This document contains information about open and resolved caveats, and operational information specific to the Dell EMC Networking operating software (OS) and the S5048F-Open Networking (ON) platform. Current Release Version: 9.14(2.10) Release Date: 2021-06-30 Previous Release Version: 9.14(2.9P1) Topics: • • • • • • • • • • • • • • • • • • • • • Document Revision History Requirements New Dell EMC Networking OS Version 9.
Requirements The following requirements apply to the S5048F-ON system.
Restrictions ● Prerequisite steps to upgrade the Dell EMC Networking OS from earlier version to 9.14.2.0 or later: 1. Uninstall the older version of the Open Automation (OA) package 2. Upgrade the Dell EMC Networking OS to 9.14.2.0 or later version 3. Install the following OA packages from the respective upgraded version: a. SmartScripts b. Puppet c. Open management infrastructure (OMI) d. SNMP MIB Prerequisite steps to downgrade the Dell EMC Networking OS from 9.14.2.0 or later to the earlier version: 1.
● When 1024 or more VNI profiles are configured, the system takes more time to load. Dell EMC recommends to restrict the VNI profiles to be less than 1000. ● If you use the interface range command to select multiple interfaces that are added to the management VRF, the ipv6 address command does not display the autoconfig option. You can configure the autoconfig command on individual interfaces.
Category Description S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer. S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around. Synopsis Synopsis is the title or short description of the issue. Release Notes Release Notes description contains more detailed information about the issue.
PR# 170039 Severity: Sev 3 Synopsis: The hop limit of neighbor advertisement packets for virtual IPv6 addresses decrease when the packets are incorrectly hashed in VLT. Release Notes: The hop limit of neighbor advertisement packets for virtual IPv6 addresses decrease when the packets are incorrectly hashed in VLT. Workaround: None PR# 170044 Severity: Sev 2 Synopsis: In certain scenarios, the switch may restart if there is an exception in the confd process.
Release Notes: Unable to change the root account password. Workaround: None PR# 170104 Severity: Sev 2 Synopsis: MIB walk displays the wrong size for the dot3adAggPortActorOperState object. Release Notes: MIB walk displays the wrong size for the dot3adAggPortActorOperState object. Workaround: None PR# 170115 Severity: Sev 3 Synopsis: The switch may encounter an exception when an incorrect length field is specified in a TACACS packet.
Upgrading the ONIE Package for the S5048F-ON System To upgrade the ONIE package, use one of the following two processes ● Zero touch (dynamic): Copy the updated ONIE installer for your system to the TFTP/HTTP server. Configure the DHCP options using the ONIE specifications shown at the following link: https://github.com/opencomputeproject/onie/wiki/ Design-Spec-SW-Updating-ONIE. ● Manual: Copy the image onto the TFTP/HTTP servers and boot ONIE.
The ONIE update mode is enabled and the ONIE prompt appears, as shown: ONIE: ONIE Update Mode ... Version : 3.38.1.1-3 Build Date: 2021-05-18T09:57-0700 Info: Mounting kernel filesystems... done. Info: Mounting ONIE-BOOT on /mnt/onie-boot ... random: fsck urandom read with 10 bits of entropy available Info: Mounting EFI System on /boot/efi ... Info: Using eth0 MAC address: 34:17:eb:37:0e:00 Info: eth0: Checking link... up.
Installing ONIE on: /dev/sda ONIE: Success: Firmware update URL: onie-updater-x86_64-dellemc_s5000_c2538-r0 ONIE: Success: Firmware update version: 3.38.1.1-3 ONIE: Rebooting... ONIE:/ # discover: ONIE update mode detected. Stopping: discover...start-stop-daemon: warning: killing process 2329: No such process done. Stopping: dropbear ssh daemon... done. Stopping: telnetd... done. Stopping: syslogd... done.
| DELL EMC Networking OS-Boot Line Interface | | EDA-DIAG | | ONIE | | | | | | | | | | | | | +----------------------------------------------------------------------------+ Use the ^ and v keys to select which entry is highlighted. Press enter to boot the selected OS, 'f' to boot FTOS, 'b' to go to BLI, 'o' to boot ONIE, 'd' to boot DIAG-OS, 'e' to edit the commands before booting or 'c' for a command-line. 3. From the menu, choose the ONIE option.
ONIE:/ # ONIE:/ # 5. At the ONIE prompt, to stop the ONIE discovery process, enter the following command: ONIE:/ # onie-discovery-stop The ONIE discovery stops, as shown: ONIE:/ # onie-discovery-stop discover: installer mode detected. Stopping: discover... done. ONIE:/ # 6. Configure an interface and assign an IP address to that interface using the following command: ONIE:/ # ifconfig eth0 10.16.129.131/16 7.
Preparing /dev/sda3 EDA-DIAG for rootfs install untaring into /tmp/tmp.PBDdoU rootfs copy done Success: Support tarball created: /tmp/tmp.PBDdoU/onie-support.tar.bz2 Updating diag-os ver in system-eeprom Diagos ver 3.38.3.1-2 Deleting TLV 0x2e: Diag Version Adding TLV 0x2e: Diag Version Programming passed.
1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the auto-boot process: Press Esc to stop autoboot ... 5 Grub 2.02~beta2 (Dell EMC) Built by root at gbbdev-maa-01 on Tue_May_18_08:55:22_UTC_2021 S5048F Boot Flash Label 3.38.2.6 NetBoot Label 3.38.2.6 2. At this prompt message, press the Esc key. The following menu appears: GNU Grub 2.
random: nonblocking pool is initialized ONIE: Using link-local IPv4 addr: eth0: 169.254.47.74/16 Starting: dropbear ssh daemon... done. Starting: telnetd... done. discover: installer mode detected. Running installer. Starting: discover... done. Please press Enter to activate this console. Info: eth0: Info: Trying DHCPv4 on interface: eth0 Checking link... up. To check the install status inspect /var/log/onie.log. Try this: tail -f /var/log/onie.
mkfs.fat 3.0.26 (2021-05-18) Done. Installing GRUB on /dev/sda4...Copying Images... Done. ONIE: NOS install successful: tftp://10.16.127.6/users/admin/ONIE-FTOS-S5048FON-9.14.2.10.bin ONIE: Rebooting... ONIE:/ # discover: installer mode detected. Stopping: discover...start-stop-daemon: warning: killing process 2638: No such process done. Stopping: dropbear ssh daemon... done. Stopping: telnetd... done. Stopping: syslogd... done.
Press Esc to stop autoboot ... 0 8. After the installation completes, the system displays the following DELL EMC prompt: DellEMC> Upgrading the CPLD The S5048F-ON system with Dell EMC Networking OS Version 9.14(2.10) requires System complex programmable logic device (CPLD) 1 revision 1, CPLD2 revision 1, CPLD3 revision 1, CPLD4 revision 1, MSS FPGA revision 0.1, MSS IAP revision 1.4, and OOB-FPGA revision 1.0. NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make any changes.
stack-unit stack-unit stack-unit stack-unit stack-unit DellEMC# 1 1 1 1 1 S5048F-ON CPLD 3 S5048F-ON CPLD 4 S5048F-ON MSS FPGA S5048F-ON MSS IAP S5048F-ON OOB-FPGA 1.0 1.0 0.1 1.4 1.0 Upgrading the CPLD Image NOTE: The upgrade fpga-image system cpld stack-unit 1 booted command is hidden when using the feature in the CLI. However, it is a supported command. To upgrade the CPLD image, follow these steps: 1. Shut down all of the interfaces on the system. INTERFACE Mode shutdown 2. Upgrade the CPLD image.
EXEC Privilege Mode show revision DellEMC#show revision -- Stack unit 1 S5048F-ON CPLD 1 -- : 1.0 S5048F-ON CPLD 2 : 1.0 S5048F-ON CPLD 3 : 1.0 S5048F-ON CPLD 4 : 1.0 S5048F-ON MSS FPGA : 0.1 S5048F-ON MSS IAP : 1.4 S5048F-ON OOB-FPGA : 1.0 NOTE: Do not power off the system while FPGA upgrade is in progress. For any queries, contact technical support.
DellEMC#May 18 13:45:16 %STKUNIT1-M:CP %DOWNLOAD-6-FPGA_UPGRADE: UNIT 1 fpga upgrade success. After the SMF MSS-IAP upgrade is successfully completed, the system re-boots automatically. 3. After the system re-boots, wait for the Dell EMC prompt. Verify the MSS-IAP version using the show revision command output.
*********************************************************************** * Warning - Upgrading FPGA is inherently risky and should * * only be attempted when necessary. A failure at this upgrade may * * cause a board RMA. Proceed with caution ! * *********************************************************************** *********************************************************************** * Warning - Please upgrade mss-iap-image to 1.4 version, before * * upgrading mss-fpga-image to 0.1 version.
2. Upgrade the OOB-FPGA image. EXEC Privilege Mode upgrade fpga-image system fpga stack-unit booted DellEMC#upgrade fpga-image system fpga stack-unit 1 booted Current information for the system: ===================================================================== Card Device Name Current Version New Version --------------------------------------------------------------------CP S5048F-ON OOB-FPGA 1.0 1.
......................................! 58994997 bytes successfully copied System image upgrade completed successfully. DellEMC#May 18 13:53:58 %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE: Upgrade completed successfully DellEMC# 3. Verify that the Dell EMC Networking OS has been upgraded correctly in the upgraded flash partition.
Control Processor: Intel Rangeley with 3 Gbytes (3203256320 bytes) of memory, core(s) 4. 16G bytes of boot flash memory. 1 54-port TE/TF/FO/FI/HU G (S5048F-ON) 48 Twenty Five GigabitEthernet/IEEE 802.3 interface(s) 6 Hundred GigabitEthernet/IEEE 802.3 interface(s) DellEMC# Upgrade the Boot Selector and Boot Flash Images from Dell EMC Networking OS To upgrade the Boot Selector and Boot Flash images from Dell EMC Networking OS, perform the following steps: 1. Upgrade the S5048F-ON Boot Selector image.
POE Capable FIPS Mode Boot Flash Boot Selector Memory Size Temperature Voltage Serial Number Part Number Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs : : : : : : : : : : : : : : : : : : : no disabled 3.38.2.6 3.38.0.
-- Unit 1 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S5048F-ON - 54-port TE/TF/FO/FI/HU G (S5048F-ON) Current Type : S5048F-ON - 54-port TE/TF/FO/FI/HU G (S5048F-ON) Master priority : NA Hardware Rev : X01 Num Ports : 86 Up Time : 1 min, 10 sec Dell EMC Networking OS Version : 9.14(2.10) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : 3.38.2.6 Boot Selector : 3.38.0.
| EDA-DIAG | | ONIE | | | | | | | | | | | | | +----------------------------------------------------------------------------+ Use the ^ and v keys to select which entry is highlighted. Press enter to boot the selected OS, 'f' to boot FTOS, 'b' to go to BLI, 'o' to boot ONIE, 'd' to boot DIAG-OS, 'e' to edit the commands before booting or 'c' for a command-line. 3. From the menu, choose the ONIE option.
Deleting partition 7 from /dev/sda Installing for i386-pc platform. Installation finished. No error reported. Uninstall complete. Rebooting... discover: Uninstall mode detected. No discover stopped. Stopping: dropbear ssh daemon... done. Stopping: telnetd... done. Stopping: syslogd... done. Info: Unmounting kernel filesystems The system is going down NOW! Sent SIGTERM to all processes Sent SIGKILL to all processes Requesting system reboot sd 4:0:0:0: [sda] Synchronizing SCSI cache Restarting system.
Support Resources The following support resources are available for the S5048F–ON system. Documentation Resources This document contains operational information specific to the S5048F–ON system. For information about using the S5048F–ON, see the following documents at http://www.dell.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.