CLI Guide

Table Of Contents
At the end of offline diagnostic tests, a test report is generated. The filename of the report is TestReport-
{CP/LP/RP}-N.txt, where {CP/LP/RP}-N identifies the CPU and CPU ID on which the diagnostics
were run: Route Processor 0, Control Processor 0, and a line-card CPU {02}. The report is stored
at flash:// and ramdisk:/diagnostic. Offline diag test reports for port extender (PE) are stored in the
following directory: flash:/default_diag_report_dir. To view the test report, use the show
file flash://filename command. A sample filename is TestReport-LP-2.
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010 and C1048P.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced the verbose option.
7.7.1.0 Introduced on the S-Series.
Related
Commands
offline system bring a switch offline to run diagnostic tests.
offline linecard
Place the linecard in the offline state in order to run the diagnostics tests.
C9000 Series
Syntax
offline linecard
Defaults none
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command-Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
Usage
Information
A warning message appears when the offline linecard command is implemented.
Warning - offline of linecard will bring down all the protocols and
the linecard will be operationally down, except for running Diagnostics.
The "reload or reset" command is required for normal operation after the
offline command is issued.
Proceed with Offline [confirm yes/no]:
To bring the linecard back to online state, reset the linecard using the reset linecard slot-id
command.
Related
Commands
diag run diagnostic tests on an offline switch.
Debugging and Diagnostics 575