Users Guide

DellEMC(conf-if-te-1/1-autoneg)#mode ?
forced-master Force port to master mode
forced-slave Force port to slave mode
DellEMC(conf-if-te-1/1-autoneg)#
For details about the speed, duplex, and negotiation auto commands, refer to the Interfaces chapter of the Dell EMC
Networking OS Command Reference Guide.
NOTE: While using 10GBASE-T, auto-negotiation is enabled on the external PHY by default, and auto-negotiation should be
enabled on the peer for the link to come up.
Adjusting the Keepalive Timer
To change the time interval between keepalive messages on the interfaces, use the keepalive command. The interface sends
keepalive messages to itself to test network connectivity on the interface.
To change the default time interval between keepalive messages, use the following command.
Change the default interval between keepalive messages.
INTERFACE mode
keepalive [seconds]
View the new setting.
INTERFACE mode
show config
View Advanced Interface Information
The following options have been implemented for the show [ip | running-config] interfaces commands for (only)
stack-unit interfaces.
When you use the configured keyword, only interfaces that have non-default configurations are displayed. Dummy stack-unit
interfaces (created with the stack-unit command) are treated like any other physical interface.
The following example lists the possible show commands that have the configured keyword available:
DellEMC#show interfaces configured
DellEMC#show interfaces stack-unit 1 configured
DellEMC#show interfaces tengigabitEthernet 1 configured
DellEMC#show ip interface configured
DellEMC#show ip interface stack-unit 1 configured
DellEMC#show ip interface tengigabitEthernet 1 configured
DellEMC#show ip interface br configured
DellEMC#show ip interface br stack-unit 1 configured
DellEMC#show ip interface br tengigabitEthernet 1 configured
DellEMC#show running-config interfaces configured
DellEMC#show running-config interface tengigabitEthernet 1 configured
In EXEC mode, the show interfaces switchport command displays only interfaces in Layer 2 mode and their relevant
configuration information. The show interfaces switchport command displays the interface, whether it supports IEEE
802.1Q tagging or not, and the VLANs to which the interface belongs.
DellEMC#show interfaces switchport
Name: TenGigabitEthernet 3/1
802.1QTagged: True
Vlan membership:
Vlan 2
Name: TenGigabitEthernet 3/2
802.1QTagged: True
Vlan membership:
Vlan 2
Name: TenGigabitEthernet 3/3
802.1QTagged: True
Vlan membership:
428
Interfaces