Administrator Guide

location-led
Toggle the location LED of a specified interface, linecard or port extender (PE) on or off.
C9000 Series
Syntax
locationled {interface interface | linecard slot-id | pe pe-id stack-unit
unit-number | rpm slot-id }{off|on}
Parameters
interface
interface
Enter the following keywords and slot/port or number information:
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
For a Gigabit Ethernet interface, enter the keyword gigabitethernet then
the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
linecard
slot-id
Enter the keyword linecard and the slot ID. The linecard slot-id range is from 0
to 9.
pe
pe-id
Enter the keyword pe and the PE ID. The range is from 0 to 255.
stack-unit
unit
number
Enter the keyword stack-unit and the stack unit number. The range is from 0 to
7.
rpm
slot-id
Enter the keyword rpm and specify the route processor slot ID. RPM slot-id values
are rpm0 and rpm1 .
on |off Turn the location LED(s) of the specified interfaces, linecard, port extenders (PE),
ports and RPMs on or off.
Default
None
Command Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
Usage
Information
When the location LED setting is turned on for a port extender (PE), the main power supply LED on the
PE flashes green light and when the location LED setting is turned off, the main power supply LED is in
a solid green state.
Thelocation-led settings are not saved through power cycles if the C1048 system is power cycled.
Example
Dell#
Dell#location-led pe 255 stack-unit 0 on
Port Extenders (PE) 1349