Administrator Guide

Version Description
8.3.12.0 Introduced on the S4810.
8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
Usage
Information
The maximum number of FCoE VLANs supported on the switch is eight.
NOTE: This command is not supported on cascade interfaces or extended ports.
show fip-snooping config
Display the FIP snooping status and configured FC-MAP values.
C9000 Series
Syntax
show fip-snooping config
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
Example
Dell# show fip-snooping config
FIP Snooping Feature enabled Status: Enabled
FIP Snooping Global enabled Status: Enabled
Global FC-MAP Value: 0X0EFC00
FIP Snooping enabled VLANs
VLAN Enabled FC-MAP
---- ------- --------
100 TRUE 0X0EFC00
show fip-snooping enode
Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address,
VLAN ID and FC-ID.
C9000 Series
Syntax
show fip-snooping enode [enode-mac enode-mac-address]
Parameters
enode-mac-
address
Enter the MAC address of the ENodes to display.
Command Modes
EXEC
FCoE Transit 663