The following describes the columns displayed in the output of the show interfaces transceiver
command:
Line Description
Rx Power
measurement
type
Output depends on the vendor, typically either Average or OMA (Receiver
optical modulation amplitude).
Tx Power
measurement
type
Output depends on the vendor, typically either Supported or Not supported.
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs between SFPs and
SFP+.
Voltage High
Alarm threshold
Displays the interface index number used by SNMP to identify the interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp High
Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage High
Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias High
Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.