Concept Guide

Table Of Contents
EXEC Privilege mode
show hardware stack-unit {112} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {112} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {112} unit {0-0} table-dump {table name}
Enabling Environmental Monitoring
The device components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
DellEMC#show interfaces tengigabitethernet 1/25 transceiver
Interface Name : TenGigabitEthernet 1/25
SFP is present
SFP+ 1638400 Serial Base ID fields
SFP+ 1638400 Id = 0x03
SFP+ 1638400 Ext Id = 0x04
SFP+ 1638400 Connector = 0x21
SFP+ 1638400 Transceiver Code = 0x01 0x00 0x00 0x00 0x41 0x84 0x80 0x55
SFP+ 1638400 Encoding = 0x00
SFP+ 1638400 BR Nominal = 0x67
SFP+ 1638400 Length(SFM) Km = 0x00
SFP+ 1638400 Length(OM3) 2m = 0x00
SFP+ 1638400 Length(OM2) 1m = 0x00
SFP+ 1638400 Length(OM1) 1m = 0x00
SFP+ 1638400 Length(Copper) 1m = 0x03
SFP+ 1638400 Vendor Rev = B
SFP+ 1638400 Laser Wavelength = 256 nm
SFP+ 1638400 CheckCodeBase = 0xe2
SFP+ 1638400 Serial Extended ID fields
SFP+ 1638400 Options = 0x00 0x00
SFP+ 1638400 BR max = 0
SFP+ 1638400 BR min = 0
SFP+ 1638400 Vendor SN = CN053HVN3711D9N
SFP+ 1638400 Datecode = 130703
SFP+ 1638400 CheckCodeExt = 0x3a
SFP+ 1638400 DOM is not supported
DellEMC#
Recognize an Overtemperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
If directly adjacent cards are normal temperature, suspect a faulty sensor.
When the system detects a genuine over-temperature condition, it powers off the card. To recognize this condition, look for the
following system messages:
CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (temperature reaches or
exceeds threshold of
[value]C)
1026
Debugging and Diagnostics