NOTE: The system reboots when the offline diagnostics complete. This is an automatic process. The following
warning message appears when you implement the offline stack-unit command: Warning - Diagnostic
execution will cause stack-unit to reboot after completion of diags. Proceed with
Offline-Diags [confirm yes/no]:y
After the system goes offline, you must reload or run the online stack-unit
stack-unit-number
command for the normal
operation.
2. Confirm the offline status.
EXEC Privilege mode
show system brief
3. Start diagnostics on the unit.
diag stack-unit stack-unit-number
When the tests are complete, the system displays the following message and automatically reboots the unit.
DellEMC#00:09:42 : Diagnostic test results are stored on file: flash:/TestReport-
SU-1.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S6000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0
DellEMC#00:09:42 : Diagnostic test results are stored on file: flash:/TestReport-
SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S6000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1
Diagnostic results are printed to a file in the flash using the filename format TestReport-SU-<stack-unit-id>.txt.
Log messages differ somewhat when diagnostics are done on a standalone unit and on a stack member.
4. View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-SU-stack-unit-id.txt
The following example shows the offline stack-unit stack-unit-number command.
DellEMC#offline stack-unit 1
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking is not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline command
is issued.
Proceed with Offline [confirm yes/no]:yes
DellEMC#Mar 12 10:32:18: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down -
stack unit offline
Mar 12 10:32:18: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te
1/1/1-/1/1/3,1/16/1-1/17/2,1/18/1-1/19/4,1/22/4-1/23/3,1/24/1-1/24/3,1/25/1-1/25/3, Fo
1/4,8,12,15,18,19,20,21,22,23,25,27,29,
The following example shows the show system brief command.
DellEMC#show system brief
Stack MAC : 10:11:12:13:14:15
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
0 Management offline S6000 S6000 9.4(0.0) 128
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
1082