Deployment Guide

Table Of Contents
Configuring a VLT Interconnect
To configure a VLT interconnect, follow these steps.
1. Configure the port channel for the VLT interconnect on a VLT switch and enter interface configuration mode.
CONFIGURATION mode
interface port-channel id-number
Enter the same port-channel number configured with the peer-link port-channel command as described in Enabling
VLT and Creating a VLT Domain.
NOTE: To be included in the VLTi, the port channel must be in Default mode (no switchport or VLAN assigned).
2. Remove any IP address from the interface if already present.
INTERFACE PORT-CHANNEL mode
no ip address
3. Add one or more port interfaces to the port channel.
INTERFACE PORT-CHANNEL mode
channel-member interface
interface: specify one of the following interface types:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
4. Ensure that the port channel is active.
INTERFACE PORT-CHANNEL mode
no shutdown
5. Repeat Steps 1 to 4 on the VLT peer switch to configure the VLT interconnect.
Enabling VLT and Creating a VLT Domain
To enable VLT and create a VLT domain, use the following steps.
1. Enable VLT on a switch, then configure a VLT domain and enter VLT-domain configuration mode.
CONFIGURATION mode
vlt domain domain-id
The domain ID range is from 1 to 1000.
Configure the same domain ID on the peer switch to allow for common peering. VLT uses the domain ID to automatically
create a VLT MAC address for the domain. If you do not configure the system explicitly, the system mac-address of the
primary will be the VLT MAC address for the domain.
To disable VLT, use the no vlt domain command.
NOTE: Do not use MAC addresses such as reserved or multicast.
2. Configure the IP address of the management interface on the remote VLT peer to be used as the endpoint of the VLT
backup link for sending out-of-band hello messages.
VLT DOMAIN CONFIGURATION mode
back-up destination {ipv4-address | ipv6-address} [interval seconds] {vrf [management
vrf-name | vrf-name]}
NOTE:
If management VRF or any specific VRF is enabled on the system, then use the back-up destination
command with vrf [management vrf-name | vrf-name]
You can optionally specify the time interval used to send hello messages. The range is from 1 to 5 seconds.
3. Configure the port channel to be used as the VLT interconnect between VLT peers in the domain.
VLT DOMAIN CONFIGURATION mode
peer-link port-channel id-number
4. Enable peer routing.
Virtual Link Trunking (VLT)
951