Reference Guide

Table Of Contents
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.1.(0.0) Introduced on the S4810; added support for OpenFlow.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
Usage
Information
For more information about VLANs and the commands to configure them, see Virtual LAN (VLAN)
Commands.
FTP, TFTP, and SNMP operations are not supported on a VLAN. MAC ACLs and IP ACLs are supported.
For more information, see Access Control Lists (ACL).
The following features are not supported on VLANs associated with an OpenFlow instance:
IPv4
IPv6
MTU
If OpenFlow VLANs are configured on the switch, spanning-tree protocols cannot be enabled
simultaneously.
Example (Single
Range)
DellEMC(conf)# int vlan 3
DellEMC(conf-if-vl-3)#
Related
Commands
interface configure a physical interface.
interface loopback configure a loopback interface.
interface null configure a null interface.
interface port-channel configure a port channel group.
show vlan display the current VLAN configuration on the switch.
shutdown disable/enable the VLAN.
tagged add a Layer 2 interface to a VLAN as a tagged interface.
untagged add a Layer 2 interface to a VLAN as an untagged interface.
intf-type cr4 autoneg
Set the interface type as CR4 with auto-negotiation enabled. To set the interface type as CR4 with autonegotiation disabled,
use the no intf-type cr4 autoneg command.
Syntax
intf-type cr4 autoneg
Defaults
Not configured
Command Modes INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
656 Interfaces