Users Guide

Dell PowerConnect 55xx Systems User Guide 155
RPS
— The device has one of two auxiliary power supplies:
Redundant Power Supply (RPS) for non-PoE devices and Modular
Power Supply (MPS) for PoE devices. Only one of these may be
present at one time. For each type of power supply, the possible
options are:
Checked
— The power supply is operating normally.
Unchecked
— The power supply is not operating normally.
Not Present
— The power supply is currently not present.
Temperature
— Displays the temperature on the device.
Fan Status
— The device has two fans. The device constantly
measures the internal temperature, and powers the fans on/off
according to the temperature. The user can set the fans to be
constantly on. The possible options are:
Checked
— The fans are operating normally.
Unchecked
— At least one of the fans is not operating
normally.
Fan Admin State
— On/Auto status that user configured in the
Edit
page.
Fan Current Level
— Specifies whether the fan is actually on or off.
2
The lower block displays the condition under which a fan will be turned on
or off.
Fan Level
— The on or off level.
Condition
— The temperature at which the fans will be turned on or
off. The device temperature is displayed in Celsius. The device
temperature threshold is 40 C (104 F).Table 11-2 displays the
temperature in Fahrenheit in increments of 5.
NOTE: It is recommended to leave Fan User Level at Auto so that the fans
operate according to the temperature of the switch.
3
To control the fans on a unit, or set the default value, click
Edit
, and enter
the fields:
Unit ID
— Select the unit ID whose fan will be adjusted.