Specifications
PowerConnect 6024/6024F Release Notes
Release Notes | Page 10
RN-CA-CLIRG-17. Reporting of
shorts in Virtual Cable Testing
(VCT).
The device reports only shorts across the cable pairs. The Virtual Cable Test
(VCT) analyzes each of the MDI pairs in the cable being tested. Typically, in a
CAT5 RJ-45 cable, the positive and negative of each pair are twisted together.
The pairs that are twisted together are identifiable: solid orange and striped
orange, solid blue and striped blue, solid green and striped green, solid brown
and striped brown are twisted together. If, for example, MDI[0]+/- pins are
connected to pairs 1,2 of the RJ45, which are connected to the orange pair,
then MDI[0]+ will be connected to the solid orange and MDI[0]- will be
connected to the striped orange. The short between wires that do not belong to
the same pair will not be reported.
RN-CA-CLIRG-18. The
responsiveness of the device
during the configuration file
copying.
While a configuration file is being copied intra-device and via TFTP (i.e.
downloaded or uploaded), the device ignores the user input sent to the device
via CLI or Web interface. Note that this behavior only applies to the session in
the context of which the copying is taking place; all other management
sessions may experience a delayed responsiveness but will accept CLI
commands and process HTTP requests.
RN-CA-CLIRG-19. The
precedence of port bound and
VLAN bound ACLs.
If an ACL X is bound to a port and the port becomes a member of the VLAN to
which a different ACL Y is bound, then the ACL Y bound to the VLAN overrides
the ACL X bound to the port.
The default rule cannot be changed manually.