Release Notes

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.1.7 Page 29
1. Changes are
not applied to
the correct
interfaces on the
pages
"System-
>sFlow-
>Sampler
Configuration"
"System-
>sFlow->Poll
Configuration"
2. Incorrect
error message is
displayed when
not configured
Receiver index
is applied
to interface on
"System-
>sFlow->Poll
Configuration"
page.
1. Changes were not applied to the correct
interfaces on the GUI pages referred to.
2. An incorrect error message was
displayed.
1. Used initialized buffers.
2. Correct the error message.
All 4.2 supported
platforms
"show ip route
configured
...longer-
prefixes" reports
that default
gateway is not
configured,
which is
incorrect.
The default gateway would not be shown on
executing "show ip route configured"
Corrected the implementation
of this command so that it
functions correctly.
All 4.2 supported
platforms
CLI command
"show ip route
192.168.2.2 /24"
not ignoring
host bits.
The user would not always get the correct
list of routes from the "show ip route"
command.
Corrected the logic in the
implementation of the "show
ip routes" command so that the
appropriate list of routes are
shown, depending upon which
optional parameters are given.
All 4.2 supported
platforms
CLI command
"show spanning-
tree detail"
missing
information.
The user could not see the configured
values for spanning tree max hops.
Changed the output of the
"show spanning-tree" and
"show spanning-tree detail"
commands to include the
configured value of max hops.
All 4.2 supported
platforms
"ipv6 pim join-
prune interval"
command does
not work
The user could not change the configuration
of the IPv6 PIM join interval.
Corrected the implementation
of this command so that it
functions correctly.
All 4.2 supported
platforms
Macro input
string does not
accept more
than 20
characters
The interface string length is limited to 20
characters for the "macro global apply"
command.
Increased the acceptable string
length for the "macro global
apply" command to 256
characters.
All 4.2 supported
platforms