42 System Firmware Version 5.1.1.7
CLI command
"show interface
detail port-
channel1" locks
up console
session
The CLI command “show interface detail
port-channel1” generates the following
errors:
Max number of lines in the scroll buffer
reached. Output will be truncated.
The scrolling issue has been
corrected.
All 4.2 supported
platforms
Creating
VLANs,
assigning ports
using vlan
membership
detail page
causes removal
from running-
config
Using web GUI to create and assign ports
via vlan membership detail page causes
previous vlan ports and sometimes previous
vlan to be removed from running-config.
VLAN creation
addition/removal behavior is
corrected.
All 4.2 supported
platforms
Assigning ACL
Priority to a
VLAN interface
does not get set
via Web UI
When binding an ACL to a VLAN
interface, via Web UI, the "Assign ACL
Priority" field does not get set as it would if
it were configured via CLI.
Web interface has been
corrected.
All 4.2 supported
platforms
Incorrect Model
numbers and
revision date in
dellref.my
The last revision date has not been revised.
This could lead a customer to believe they
do not need to update their MIB file.
LAST-UPDATED "200311210000Z" -- 21
Nov 2003 12:00:00
The MIB has been corrected.
Administrators are advised to
load the new MIBs when
updating to this release.
All 4.2 supported
platforms
Links do not
show status
Link dependency CLI "show link-
dependency" shows "Member ports" and
"Ports depended on" port numbers along
with group id, but does not show the status
of the members or the depended-on ports.
The display has been updated
to show the requested
information
All 4.2 supported
platforms
M8024 does not
save complete
MST vlan
configuration
Show spanning-tree mst-config not
working.
All MSTP configurations are
now saved.
PCM8024
Need to increase
the VRRP
routing
instances or
VRID to greater
than 50
Previous limit was 20.
VRRP instances are now set to
50.
All 4.2 supported
platforms
On the 8024F,
inserting or
removing the
cable on ports 1
and 2 causes
both ports to
shut down
briefly
The PowerConnect 8024F ports 1 and 2 will
flap briefly when cables are removed and
reinserted.
All inter-phy operation is
fixed.
PC8024F
The CLI
command
terminal length
is not setting
terminal length
value
When executing the command terminal
length <value>, the value is not updated
after execution.
Terminal length settings now
take effect immediately.
All 4.2 supported
platforms
The Service tag
is being deleted
on modular
platforms.
When executing the “show system id” is not
showing the service tag on modular
platforms.
The service tag was
accidentally being deleted and
is now being saved correctly.
All 4.2 modular platforms.