Release Notes
Table Of Contents

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.1.7 Page 45
Summary User Impact Resolution Affected
Platforms
sFlow: Limit of 32 for the
number of interfaces for which
sFlow can be enabled
Current limit of 32 for the number of
interfaces for which sFlow can be enabled.
Changed the limit to allow
all sFlow instances.
All Platforms
sFlow: Formatting errors with
some of the records
Some of the sFlow records had formatting
errors.
Corrected sFlow header
problems.
All Platforms
sFlow: The sample Pool field
is not being incremented
properly
Sample pool field will not be incremented
in the sFlow packet sent to the collector.
Corrected sample pool field
error.
All Platforms
sFlow: The sFlow agent field
isn't being filled in
The sFlow agent field isn't being filled into
sFlow Packet.
Corrected problem adding
sFlow agent address.
All Platforms
Stack module inserted in Bay
1 and SFP+ module in Bay 2
With the presence of stack module at bay1,
SFP+ module in bay2 will not get detected
until the stack-module at bay1 is removed.
Corrected error that
prevented the detecting of
SFP+ module in bay 2.
PCM6220
CLI "switchport general
acceptable-frame-type"
different options than GUI
The CLI "switchport general acceptable-
frame-type" contains different options than
GUI.
Options are now the same. All Platforms
startup-config cannot be
restored via tftp
TFTP script download or saved script
validation will leave the DUT in an
unusable state.
Corrected script validation
problem.
All Platforms
"show ip ospf database" does
not respect configuration of
"terminal length 0"
The CLI handler of the "show ip ospf
database" command does not consider the
terminal length configuration.
Corrected terminal length
configuration handling.
All Platforms
Occasionally, "clear config"
from console triggers
wio_api.c traceback
Occasionally, "clear config" from console
triggers wio_api.c traceback
Corrected “clear config”
internal message error.
All Platforms
Radius config stops working
after reboot.
Radius config stops working after reboot,
needs to be removed and re-added in order
to work again.
Corrected error in Radius
user authentication
processing.
All Platforms
ISDP timers running fast. ISDP entries are timing out and dropping
off the list before the next update comes
in.
Corrected an error in the
ISDP timer disable
processing.
All Platforms
VRRP hang VRRP loss of mastership causes the switch
to hang.
Corrected an error in the
VRRP processing of the
new IP address.
All Platforms
IPMC error messages and
forwarding issue.
Error messages indicating that IPMC table
are not set correctly in hardware.
Corrected error message
processing which generated
false error messages.
All Platforms
Dynamic LAG Ports are
flapping/continuous trace
messages.
Lags do not stay up on combo ports. Corrected an error in
mapping the physical ports
to a LACP logical port.
All Platforms
Simple Switch should have FC
enabled by default
Enable Flowcontrol on simple mode. Flowcontrol enabled on
simple mode.
All Platforms
Need to change message on
console when try to
downgrade anything below
4.1.0.19 release for new DDR
If a switch contains new DDR,
downgrading to 4.1.0.19 is not allowed.
Modified the downgrade
message.
PCM8024
PCM8024-k
(with new
DDR)