Release Notes
Table Of Contents

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.1.7 Page 3
Firmware Downgrade
Downgrading from 5.1.1.7 to an earlier release is supported on most PowerConnect series switches (except PC81xx series
with B1 CPU versions, see note below); however, migration of configuration information from a later release to an earlier
release is not supported. The existing configuration may or may not work with the earlier version of firmware, therefore, it is best
to be physically present at the switch site and to be prepared to access the switch over the serial port if necessary when
downgrading firmware.
Auto-downgrade of a stack is not enabled by default. If downgrading a stack, be sure to enable auto-downgrade before activating
the earlier versions of firmware on the stack master.
Recent versions of the PowerConnect 81xx series switches support newer versions of CPU (B1). The B1 version of CPU
requires firmware release version 5.1.0.1 or later and cannot be downgraded to earlier firmware releases. In addition, if this unit is
to be deployed as a member within a stack, the entire stack will be required to run 5.1.0.1 or later firmware. Here are some steps
to help determine what CPU is in the PowerConnect 8100 Series switch:
1. Run show version from the CLI prompt.
2. If there is no CPU version line, then the stack is running 5.0.x.x firmware. Since 5.0.x.x can only run on
A1 CPU switches, then all switches in the stack (or a standalone) contain A1 CPUs.
3. If there is a CPU version line (like below):
CPU Version....................... XLP308H-A1
(It will display the CPU version in the last two characters - either A1 or B1).
4. On a stack, run show version m where m is the unit number assigned to the stack member to see each CPU
version for each member in the stack.
In addition here are the part numbers for reference:
Part Numbers for PowerConnect 81xx
A1 CPU
B1 CPU
PowerConnect 8132 (US, Canada, Mexico, South America)
TRJ78
PTM0F
PowerConnect 8132 (all other countries) 0C90P X20W5
PowerConnect 8132F
(US, Canada, Mexico, South America)
W0HV1
NWHGV
PowerConnect 8132F (all other countries)
7D1GN
KWHG3
PowerConnect 8164 (US, Canada, Mexico, South America)
H0F6C
N00C1
PowerConnect 8164 (all other countries)
P8RHX
Y2FJ0
PowerConnect 8164F (US, Canada, Mexico, South America)
VTWN8
4PHP2
PowerConnect 8164F
(all other countries)
1JWM5
8KHT1
Recent versions of the PowerConnect M8024-K modular switches have hardware changes that require firmware version 4.1.0.19
or higher. PowerConnect M8024-K with a new PPID label cannot be downgraded to the firmware version below 4.1.0.19. If a
downgrade is attempted, the firmware activation procedure will detect that earlier firmware version is not compatible with the
switch hardware and abort the activation procedure. Any PowerConnect M8024-K with the old PPID label can accept any
version of the switch firmware.
MODEL OLD PPID NEW PPID
M8024K
2F07F A00 2F07F A01
57821 A00 57821 A01