Release Notes
Table Of Contents

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.1.7 Page 49
Summary User Impact Resolution Affected
Platforms
FAN LED graphic on web page
needs to glow in RED when
FANs are not operational
(stopped).
Inability to determine switch status. Web page has been corrected All
Platforms
Incorrect command is being
displayed in running-config,
when boot host dhcp is
disabled.
Potential operator confusion regarding web
page operations.
The running config now
shows the correct
configuration
All
Platforms
DUT crashes while configuring
max dynamic VLANs.
Network outage possible. The PowerConnect does not
crash when using maximum
dynamic VLANs
All
Platforms
Manager of the stack is
changing when trying to learn
maximum number of VLANs
using GVRP.
Potential operator confusion regarding
switch operations.
The stack manager does not
change during learning with
GVRP
All
Platforms
Switch prompts to save config
data when no changes have
been made
Potential operator confusion regarding
switch operation.
The switch no longer
prompts to save config data
if no changes have been
made
All
Platforms
Crash while RFC3918 Group
Capacity test is running
Network outage possible. The PowerConnect switch
runs the RFC3918 test
without crashing
All
Platforms
'no' version of 'key' command
is not implemented
Potential operator frustration with switch
management.
The no key command is
implemented to return the
key configuration to the
default.
All
Platforms
Password is not accepting
quotation ( " ) character
Potential operator confusion regarding
switch configuration.
Passwords can be enclosed
in quotes (contain embedded
blanks). A password may not
contain a quote. The
accepted character set and
length is documented in the
CLI reference manual.
All
Platforms
Incorrect warning message
displayed while executing the
command "boot system <unit>
image1"
Potential operator confusion regarding
switch operation.
The error message has been
corrected to indicate that the
unit selected for reboot does
not exist.
All
Platforms
IPV6 command displays wrong
output
Potential operator confusion regarding
switch operation.
The IPv6 output has been
corrected to remove the
duplicate display lines in
show ipv6 help.
All
Platforms
LLDP-MED log messages
showing 5 sec difference in
entry age out information
Potential operator confusion regarding
switch operation.
The LLDP timer has been
updated to account for
processing skew.
All
Platforms
DHCPv6 web issues Potential operator confusion regarding
switch configuration.
The acceptable character
sets are documented in the
CLI Reference guide.
All
Platforms
LLDP MED application should
not allow configuration of
location and inventory transmit
TLV's as underlying
application not present
Potential operator confusion regarding
switch configuration.
Location and inventory
TLVs cannot be enabled for
transmission in LLDP MED.
All
Platforms