Release Notes

52 System Firmware Version 5.1.1.7
Summary
User Impact
Resolution
Affected
Platforms
Unable to execute the
command dot1x timeout tx-
period 1
Potential operator confusion over switch
operations.
This command is accepted
with a timeout period of 1
second. Corrected range
check on input.
All
Platforms
In switching> network security
>dot1x authentication web
page in read-only user mode,
the Re-Authenticate Now
check box can be checked
Potential operator confusion over switch
operations. Possible security issue.
Read-only properties are set
for the check box
All
Platforms
System Device information
web page LED information not
in sync with front panel LED
information.
No Potential operator impact expected. This issue was regarding
various stylistic aspects of
the system device web page.
The system device web page
conforms to the requirements
as it exists and does
necessarily match the CLI
with regarding to
capitalization or naming
conventions
All
Platforms
DHCP snooping static binding
thru DHCP request is denied as
this is an expected behavior.
Potential operator confusion over switch
operations.
Removed the log message
indicating that a bound
DHCP client with an existing
binding sent a DISCOVER.
Added a counter for this
condition to the DHCP
debug statistics.
All
Platforms
Mode of transfer is displaying
unknown,” while
downloading the code from ftp
Potential operator confusion over switch
operations.
ftp transfer mode is
displayed
All
Platforms
Allow disabling and enabling
of terminal paging
Potential operator frustration over switch
configuration.
The terminal length
command is now
implemented.
All
Platforms
Web does not allow to
configure image descriptor to
its max length i.e. 255
characters.
Potential operator confusion over switch
operations.
Images descriptors up to
255 characters are allowed
All
Platforms
CDP (ISDP) is active on port-
channels instead of the member
Ethernet interfaces. For
dynamic LAGS, the ISDP
information is not exchanged
on the interface until the port-
channel becomes active.
Potential operator confusion over switch
operations. Inability to interoperate with
other switches.
CDP is active on the
member ports for dynamic
LAGs when the LAG is
active.
All
Platforms
CLI Manual Has No Index Potential operator frustration over switch
configuration.
The CLI manual has an
index.
All
Platforms
Script validation is fails when
max SNTP servers are
configured.
Potential operator confusion over switch
configuration.
Corrected CLI validation
check so that existing server
can be entered multiple
times.
All
Platforms
Configured SYSLOG server
parameters cannot be updated
without deleting and re-
configuring
Potential operator frustration over switch
configuration.
Syslog server parameter can
be updated in the CLI
without deleting the server.
All
Platforms