Release Notes

66 System Firmware Version 5.1.1.7
Summary
User Impact
Workaround
PC8024F Stacking -
CLI/WebUI : stack-ports
counters value is always
zero
CLI/WebUI shows the stack-ports counters value
as zero after stack is formed.
None Stack-Ports counter values as zero
doesn’t affect the PC8024F stacking
functionality.
CLI command "no snmp-
server community-
group" doesn't work
CLI command “no snmp-server community-
group” is not available.
None
Dot1x ias local
authentication method
not working
The internal database feature, which is a Dell
specific feature, is not working correctly because
this feature requires a user to authenticate using
MD5, which is not supported by Windows at this
time.
Use any other form of dot1x authentication.
"ipv6 pim join-prune
interval" command is not
working
CLI command “"ipv6 pim join-prune interval 30"
does not change the default interval value from
60
None
Incorrect status being
reported with show
interfaces commands
When PowerConnect 8024F combo ports 21 and
22 are used for stacking, the show interfaces
status command and show interfaces media-type
commands report the status to be Detached and
Down.
None
Power supply
descriptions should be
modified as "Internal"
and "Remote" or
"External" for main and
secondary power
supplies respectively in
show system.
There is no impact to the user.
None
M8024-k Internal ports
are up during most of the
switch POST
Network operators may experience a single
bounce during reboots of the M8024-k.
None
M8024, M6220,
M8024k, PC8024F -
Extra Lines and Tabs in
CSR Cause CA
Submittal Troubles
CSR may be rejected by Certificate Authority
Users can hand edit the CSR to left align all
rows and eliminate blank lines before
submission to the CA.
Sflow configurations do
not get saved to the
config
The operator entered a sflow command that takes
a timeout value which makes the sflow
configuration valid only for a fixed period of
time. As the configuration is temporary (bound
by the timeout value), it is not shown in running-
config. Storing the vale in the running
config/startup config would be an error as the
time period may have already expired.
The configuration will show in the running
config if the command is used with the
"notimeout" option, e.g.
sflow 1 destination owner 1 notimeout
Password strength -
minimum characters not
enforced
Operator may become confused regarding switch
operations.
As is documented in the CLI Reference
Manual, the password strength minimums do
not become effective until the user has
configured a non-zero value for passwords
strength minimum character-classes. Please
refer to the documentation for passwords
strength minimum character-classes