Command Line Interface Guide
472 Green Ethernet Commands
User Guidelines
Cable diagnostics (show copper-ports commands) may give misleading
results if green mode is enabled on the port. Disable green mode prior to
running any cable diagnostics. EEE and energy-detect modes are only
supported on PC81xx 10G ports.
green-mode eee-lpi-history
Use the green-mode eee-lpi-history command in Global Configuration mode
to configure the Global EEE LPI history collection interval and buffer size.
This value is applied globally on all interfaces on the stack. LPI history is only
collected on combo ports when the copper port is enabled. Use the no form of
the command to set the sampling interval or max-samples values to the
default.
Syntax
green-mode eee-lpi-history {sampling-interval
30 sec
–
36000 sec
| max-
samples
1
-
168
}
Parameter Description
Default Configuration
The sampling-interval default value is 3600 seconds and the max-samples
default value is 168.
Command Mode
Global Configuration
User Guidelines
eee and energy-detect modes are only supported on PC81xx 10G ports.
Parameter Description
sampling-interval The interval in seconds at which power consumption data
needs to be collected.
max-samples Maximum number of samples to keep.
2CSPC4.X8100-SWUM100.book Page 472 Wednesday, August 29, 2012 6:23 PM