Hardware Reference Manual

Brocade 6505 Hardware Reference Manual 37
53-1002449-01
Access Gateway default port mapping
A
The serial port can be used to connect to a workstation to configure the switch IP address before
connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600
baud, 8 data bits, and no parity, with flow control set to None.
Table 12 lists the serial cable pinouts.
Access Gateway default port mapping
Table 13 lists the port mappings of F_Ports to N_Ports.
Regulatory compliance
This section describes the following regulatory compliance requirements for the Brocade 6505: It
contains:
“FCC warning (US only)” on page 38
“German statement” on page 38
“KCC statement (Republic of Korea)” on page 38
“VCCI statement (Japan)” on page 38
“Power cords (Japan DENAN)” on page 39
“Chinese statement” on page 39
“BSMI statement (Taiwan)” on page 39
“CE statement” on page 39
TABLE 12 Serial cable pinouts
PIN Signal Description
1Not supported N/A
2Not supported N/A
3UART1_TXD Transmit data
4GND Logic ground
5GND Logic ground
6UART1_RXD Receive data
7Not supported N/A
8Not supported N/A
TABLE 13 Access Gateway default port mapping
Total ports F_Ports N_Ports Default port mapping
24 0-15 16-23 0,1 mapped to 16
2,3 mapped to 17
4,5 mapped to 18
6,7 mapped to 19
8,9 mapped to 20
10,11 mapped to 21
12,13 mapped to 22
14,15 mapped to 23