Messages Reference Guide
252 Fabric OS Message Reference
53-1002749-01
CVLC-1022
5
CVLC-1022
Message User provided key ID <Key ID provided by the user> is ignored while data state is
clear text. Container: <Target container name>, Initiator: <Initiator physical
WWN>, LUN ID: <LUN ID>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the key ID provided is ignored because the data state is cleartext.
Recommended
Action
No action is required.
CVLC-1023
Message Rebalance recommended on EE: <EE name>.
Message Type LOG
Severity INFO
Probable Cause Indicates that due to container configuration changes, weights are not balanced on OB1s.
Recommended
Action
Run the cryptocfg --rebalance command to increase system performance.
CVLC-1024
Message Device Decommission operation <Decommission state (succeeded/failed)>. Container:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the device decommission process has either succeeded or failed.
Recommended
Action
No action is required.