Messages Reference Guide
256 Fabric OS Message Reference
53-1002749-01
CVLC-1034
5
CVLC-1034
Message Rekey failed on Container: <Target container name>, Initiator: <Initiator physical
WWN>, LUN ID: <LUN ID> because <Failure reason>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the first-time encryption, key expired, or manual re-key operation failed.
Recommended
Action
No action is required.
CVLC-1035
Message A decommissioned LUN has been added back as encrypted LUN. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that a decommissioned LUN has been added as an encrypted LUN.
Recommended
Action
Perform the following steps.
1. Remove the LUN from the container.
2. Add the LUN back as a cleartext LUN.
3. Modify the LUN policy to encrypt.
CVLC-1039
Message Refresh DEK operation <Refresh DEK status (SUCCEEDED/FAILED)>. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type LOG
Severity INFO
Probable Cause Indicates the status of the refresh DEK operation.
Recommended
Action
No action is required.