Fabric OS FCIP Administrator’s Guide 11
53-1002474-01
FX8-24 blade license options
2
• 10 Gbps mode: VE_Ports 12 through 21 use xge1; VE_Ports 22 through 31 use xge0
NOTE
In 10 Gbps mode, you can also configure VE_Ports 12 through 21 to use port xge0 as a
crossport and VE_Ports 22 through 31 to use port xge1 as a crossport. Refer to “Crossports”
on page 13 for more information.
Considerations for using VE_Ports and FCIP tunnels
Consider the following when using VE_Ports and tunnels:
• Total bandwidth cannot exceed 20 Gbps for VE_Ports.
• As a best practice, Fibre Channel traffic through a VE_Port tunnel should not exceed
recommended oversubscription guidelines. General guidelines include 2-to-1 oversubscription
without compression (for example, 1 Gbps over a 500 Mbps tunnel) and 4-to-1
oversubscription with compression.
• VE_Ports or VEX_Ports cannot connect to the same domain at the same time as Fibre Channel
E_Ports or EX_Ports.
FCIP trunking capacity on the FX8-24 blade
FCIP trunking provides load leveling and failover capabilities through the use of multiple FCIP
circuits:
• FCIP tunnels using 1 GbE or 10 GbE ports can have up to ten FCIP circuits spread across any
GbE ports.
• You can define up to eight IP addresses (0 through 8 minus the default IPv6 “link-local”
address) for a GbE port.
• Up to four FCIP circuits can be configured per 1 GbE port, each requiring a unique IP address.
• Up to ten FCIP circuits can be configured per 10 GbE port, each requiring a unique IP address.
• A single circuit between 1 GbE ports cannot exceed 1 Gbps capacity.
10 GbE port considerations
Enhanced 10GbE port operation is different than 1 GbE port operation and requires special
considerations when configuring circuits, tunnels, failover operations, and bandwidth.
Multigigabit circuits
For each 10 GbE port, you can configure multigigabit circuits. For example, a single 10 Gbps circuit
or two 5 Gbps circuits can be configured per port. A limit of 10 FCIP circuits can be configured on a
single port. The blade at each end of the tunnel must be running Fabric OS v7.0 and later if the
committed rate for circuits exceeds 1 Gbps.The maximum committed rate for a circuit between 10
GbE ports is 10 Gbps.