Reference Guide
Fabric OS FCIP Administrator’s Guide 55
53-1002474-01
FCIP design considerations for the FR4-18i blade
3
FR4-18i blade ports
Each Brocade FR4-18i blade presents 16 FC ports and 16 virtual ports. Each GbE interface can
support up to eight FCIP tunnels which are represented as eight virtual ports on ge0 and 8 virtual
ports on ge1. The mapping of tunnels on ge0 and ge1 to virtual port numbers is represented in
Table 9.
FCIP design considerations for the FR4-18i blade
The following are general design considerations when configuring the Brocade FR4-18i blade:
• The Brocade FR4-18i blade can have up to eight tunnels per GbE interface.
• Source and destination IP addresses are defined on the FCIP tunnel. FCIP circuits are not
supported; therefore, FCIP trunking is also not supported.
• If the source and destination IP addresses are not on the same subnet, an IP static route must
be defined.
• FCIP is not supported through Network Address Translation (NAT).
• When an FR4-18i blade is installed on a DCX that includes FC8-64 blades, ports 0 through 55
of the FC8-64 blade can route to FR4-18i VE_Ports and vice versa, but ports 56 through 63
cannot route to FR4-18i VE_Ports. If ports 56 through 63 and FR4-18i VE_Ports are on the
default switch or on the same logical switch in a Virtual Fabrics (VF) configuration, those ports
will not be able to send traffic between each other. There are no general restrictions regarding
FR4-18i blades and FC8-64 blades coexisting in the same chassis. Furthermore, there are no
specific coexistence restrictions in the same chassis if ports 56 through 63 of the FC8-64
blade and the FR4-18i blade VE_Ports are on different logical switches or not part of the
default switch and therefore are not allowed to route to each other. This restriction does not
apply to the DCX-4S. On a DCX-4S, ports 0 through 63 of the FC8-64 blade can route to
FR4-18i VE_Ports and vice versa.
• The FR4-18i and FX8-24 blades cannot be supported in the same chassis using Fabric OS v7.0
and later.
TABLE 9 FR4-18i blade tunnel and virtual port numbering
GbE ports Tunnels Virtual ports
ge0 0
1
2
3
4
5
6
7
16
17
18
19
20
21
22
23
ge1 0
1
2
3
4
5
6
7
24
25
26
27
28
29
30
31